Produk ini kompatibel dengan atau cocok untuk peralatan dan aplikasi dari merek-merek berikut, hanya sebagai referensi pemilihan. Merek dagang dimiliki oleh masing-masing pemiliknya; tidak menyiratkan kemitraan atau dukungan.
The Jyntrel V-Bank high-efficiency filter is a compact air filter built around a V-shaped bank of glass-fibre filter media, rated for operation at 2.5 m/s face velocity and available in efficiency classes from M6 to H14. It removes fine particulate matter from supply air in high-volume HVAC and clean-air systems, and is intended for engineers specifying air handling units, make-up air units, fan filter units and turbine intake systems. Use it where airflow is high, pressure drop matters and the filter must hold its efficiency across the whole face.
Start with the air path. In a V-bank filter, air enters the open face, passes through several panels of glass-fibre media arranged in a V, and leaves through the opposite face. Because the media area is larger than the face area, the air velocity through the media is lower than the face velocity, which keeps resistance down and dust holding up. Jyntrel rates this filter at 2.5 m/s face velocity, a high figure for a high-efficiency filter, so it suits systems moving large air volumes through a compact filter section.
The housing matters as much as the media. The filter is available with an ABS high-strength plastic frame or a galvanized iron frame. Both are designed to resist wind pressure and to stay rigid when the system runs at full flow. A rigid frame keeps the media pack in place, prevents bypass and protects efficiency at the corners and edges. If your duct or AHU imposes vibration, repeated fan starts or a long unsupported span, tell us; frame choice and panel count can be matched to the duty.
Environment sets the limits. Standard versions are intended for general ventilation and cleanroom supply air. For corrosive, high-humidity or high-temperature streams, share the details before selection so that frame and media options can be reviewed. The filter is not a substitute for pre-filtration: upstream G4 and F8 stages protect the V-bank, extend service life and keep final resistance predictable.
Efficiency grades run from M6 and F7–F9 through E10–E11 to H13 and H14. The highest grades are specified for cleanrooms and critical supply air, where particles at the most penetrating particle size must be captured with a high margin. The V arrangement gives a large media area in a short depth, so a 292 mm deep filter can handle high airflow without an oversized duct section. That combination of high face velocity and high efficiency is the reason V-bank filters are common in semiconductor, pharmaceutical and data-centre air systems.
Lower resistance translates directly into fan energy. By spreading flow across a larger media area, the V-bank layout reduces the pressure the fan must overcome compared with a flat panel of the same face size and efficiency. The benefit shows up in the operating budget: a lower initial resistance and a slower rise in resistance as dust loads both cut electricity use and lengthen the interval between changes. Jyntrel supplies the filter with a stated grade and frame so that the AHU designer can calculate system resistance with confidence.
V-bank filters are selected by airflow and resistance, not by face size alone. To propose the right configuration, Jyntrel needs the following from you:
Jyntrel supports OEM and ODM work on this product: non-standard sizes, efficiency grades and airflow ratings can be customised, and frame material, logo and packaging can be adapted. More than 1,000 filter solutions have been developed across the company's history, so unusual dimensions or panel counts are routine rather than exceptional.
| Item | Detail |
|---|---|
| Product name | V-Bank / V-Cell medium and high-efficiency air filter |
| Efficiency | M6 / F7 / F8 / F9 / E10 / E11 / H13 / H14 |
| Filter media | High-quality ultra-fine glass-fibre filter paper |
| Frame material | ABS high-strength plastic or galvanized iron |
| Rated operating face velocity | 2.5 m/s (designed for high-airflow, high-throughput systems) |
| Typical applications | Pharmaceutical GMP workshops, semiconductor cleanrooms, hospital operating rooms, gas turbine intake systems, commercial building central AHUs |
| Common size references (W × H × D) | 24×24×12 in (592 × 592 × 292 mm); 20×24×12 in (490 × 592 × 292 mm); 12×24×12 in (287 × 592 × 292 mm) |
| Production certification and customisation | In-house CNAS-accredited testing centre; ISO 9001 and IATF 16949 certification; full OEM customisation of non-standard sizes, efficiency and airflow |
Wherever air volume is high and particle control is strict, the V-bank format earns its place. In semiconductor and microelectronics plants it serves cleanroom supply and make-up air, where a high face velocity keeps the air handling plant compact. In pharmaceutical GMP workshops it protects product areas against particulate carry-over. In hospitals it is used in operating room air systems. In energy and metal production it appears in gas turbine intake systems, where large air volumes must be cleaned before the compressor. In commercial buildings it fits central AHU filter sections, and in data-centre cooling it supports high-flow air paths with a low pressure penalty.
Supply stability comes first. Jyntrel runs multiple automated production lines with a monthly capacity of millions of pieces, and has exported filtration products to Europe, the United States, Japan and Korea for more than 20 years. The manufacturing base covers 50,000 m² in Zhongshan, Guangdong, China, including six clean workshops with a combined area of 20,000 m². Filters are assembled in these controlled spaces to limit contamination during production.
Quality is checked through the full process: incoming material inspection, in-process inspection and outgoing inspection. The in-house laboratory is accredited by CNAS (China National Accreditation Service for Conformity Assessment) and can issue test reports covering filtration efficiency, dust holding capacity and resistance. The company holds ISO 9001, ISO 14001 and ISO 45001 certification, and obtained IATF 16949 automotive quality management certification in 2024. Products meet REACH and RoHS requirements, and compliance documents can be provided with orders.
To receive a technical proposal and quotation for the Jyntrel V-bank high-efficiency filter, please send us your device or vehicle model if relevant, the required size or a drawing, the airflow or water flow, the operating conditions (temperature, humidity, dust load, pre-filtration), and the quantity you plan to order. Include the target efficiency class and any standard you must meet. Our team will respond with a configuration that fits your air path and budget. Contact Jyntrel with your operating data and we will take it from there.
Yes. The Jyntrel V-bank filter is rated for a face velocity of 2.5 m/s, which is high for a high-efficiency filter. The V-shaped media pack gives a larger filtration area than the face size, so the air speed through the media stays lower and resistance is kept in check.
We need the rated airflow or face velocity at the filter, the allowable initial and final resistance, and the required efficiency class. The available width, height and depth, or a drawing, help us confirm the frame and panel count. Operating temperature, humidity and upstream pre-filters complete the picture.
Yes. Jyntrel offers OEM and ODM customisation on this product, including non-standard sizes, efficiency grades from M6 to H14, airflow ratings, frame material, logo and packaging. Share your space constraints and target efficiency and our team will propose a configuration within the 1,000-plus filter solutions developed by the company.
Sample quantities are available under the product-specific sample policy; please state the size and efficiency you need when you inquire. Our team will confirm the sample arrangement, test documentation and delivery details with your inquiry so you can validate fit and performance in your own air path.
MOQ and lead time are set per configuration and are confirmed at quotation. Because V-bank filters are built to size and efficiency, the order quantity, frame choice and production schedule all affect timing. Send your requirement and our team will return the specific MOQ and delivery schedule for your configuration.
Replacement depends on the upstream pre-filtration, dust concentration and running airflow. A common guide is to change the filter when its resistance reaches twice the initial value, or when system airflow falls below the design figure. With suitable G4 and F8 pre-filters, service intervals can be extended, and we can help you plan them.
The Jyntrel laboratory is CNAS-accredited and can issue reports for filtration efficiency, dust holding capacity and resistance. Manufacturing follows ISO 9001, ISO 14001 and ISO 45001 systems, with IATF 16949 certification obtained in 2024. Products meet REACH and RoHS requirements and compliance documents are available.
Standard versions are intended for general ventilation and cleanroom supply air. For corrosive, high-humidity or high-temperature streams, share the operating conditions before selection so that frame and media options can be reviewed against your duty. Our team will advise on the most suitable configuration for your air path.